Send Message
products

Twin And Earth Cable

Basic Information
Place of Origin: China
Brand Name: Zion communication OR OEM
Certification: CE, RoHS, VDE, UL, CUL, LPCB
Model Number: Twin And Earth Cable
Minimum Order Quantity: 20 KM
Packaging Details: 100M, 200M, Roll, Carton
Delivery Time: 25 working days
Payment Terms: T/T, L/C
Supply Ability: 1000KM / Month
Detail Information
Conductor: RE: 1mm² To 2.5mm²: Class 1 Solid Copper Circuit Protection: 1mm² To 2.5mm²: Class 1 Solid Copper
Conductor (Earth): 4mm² To 16mm²: Class 2 Stranded Copper Insulation: Polyvinyl Chloride (PVC)
Sheath: Polyvinyl Chloride (PVC)

Product Description

Twin And Earth Cable

Twin And Earth Cable 0

Twin And Earth Cable 1

 

Application:     Cable Standards:
This cable has a bare protective conductor
plus 1, 2 or 3 cores.
Used for fixed installations in dry or
damp premises clipped direct to surface,
on trays or in free air.
Where mechanical protection is required,
it can be laid in conduit or trunking.
    BSEN 50363-3, BS 6004
    Flame Retardant according to IEC/EN 60332-1-2
                         
                         
                         
 
Product Description:
Conductor RE: 1mm² to 2.5mm²: Class 1 solid copper
RM: 4mm² to 16mm²: Class 2 stranded copper
Circuit Protection
Conductor (Earth)
1mm² to 2.5mm²: Class 1 solid copper
4mm² to 16mm²: Class 2 stranded copper
Insulation Polyvinyl Chloride (PVC)
Sheath Polyvinyl Chloride (PVC)
 
Characteristics:
Voltage Rating Uo/U 300/500V
Temperature Rating -5°C to +70°C
Minimum Bending Radius Fixed: 6 x overall diameter
 
Core Identification:
                                                   
1 Core:   Brown                                
                                                   
2 Core:   Brown     Blue                          
                                                   
2 Core:   Brown     Blue                          
                                                   
3 Core:   Brown     Blue     Black                      
                                                   
Should not be installed at temperatures below 0°C or above +60°C
                                                   
                                                   
                                                   
                                                   
                                                   
 
Dimensions:
Zion Code No. Of
Cores
Nominal Cross Sectional Area(mm²) Nominal Thickness
Of Insulation
(mm)
Nominal overall
diameter
(mm)
Nominal overall
diameter
(mm)
Nominal overall
diameter
(mm)
Nominal overall
diameter
(mm)
Nominal
Weight
Kg/km
TAEC2x1.0 2 1 1 1 0.6 0.9 4.35 x 7.95 68
TAEC2x1.5 2 1.5 1 1 0.7 0.9 4.85 x 8.90 87
TAEC2x2.5 2 2.5 1 1.5 0.8 1 5.65 x 10.65 120
TAEC2x4.0 2 4 2 1.5 0.8 1 6.30x 11.95 172
TAEC2x6.0 2 6 2 2.5 0.8 1.1 7.10x 13.70 235
TAEC2x10 2 10 2 4* 1 1.2 8.70x 17.25 373
TAEC2x16 2 16 2 6* 1 1.3 9.85 x 20.0 530
TAEC3x1.0 3 1 1 1 0,6 0.9 4.35 x 9.80 91
TAEC3x1.5 3 1.5 1 1 0.7 0.9 4.85 x 11.2 115
                                                   
Conductors:
  Nominal Cross Sectional Area
(mm²)
MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC
ohms/km
   
  Plain Wires    
  1 18.1    
  1.5 12.1    
  2.5 7.41    
                                                   
Class 2 Stranded Conductors for Single Core and Multi-Core Cables
  Nominal Cross Sectional Area (mm²) Current Carrying Capacity Amps MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC
ohms/km
  Annealed Copper Conductor
  Circular Plain Wires
  4 7 4.61  
  6 7 3.08  
  10 7 1.83  
  16 7 1.15  
The above table is in accordance with EN 60228

Contact Details
isaac lee

Phone Number : +8613285710822

WhatsApp : +8615088607575