logo
Send Message
products

FPL Shielded Fire Alarm Cable 18 AWG 2 Core Non-Plenum PVC for Smoke Detectors

Basic Information
Place of Origin: China
Brand Name: Zion communication OR OEM
Certification: ISO, CE, RoHS, UL
Model Number: Fire Alarm Cable 18 AWG FPL
Minimum Order Quantity: 20 KM
Packaging Details: 500FT, 1000FT, Wooden Reel, Carton
Delivery Time: 25 working days
Payment Terms: T/T, L/C
Supply Ability: 1000KM / Month
Detail Information
Conductor: Solid Bare Copper Insulation: PVC Non-Plenmum
Shield: Aluminum / Mylar Drain Wire: Tinned Copper Wire
Jacket: PVC Non-Plenmum Color: Red
Package: 500FT, 1000FT, Wooden Reel, Carton
Highlight:

fire proof cable

,

fire alarm system cable


Product Description

 

FPL Shielded Fire Alarm Cable 18 AWG 2 Core Non-Plenum PVC for Smoke Detectors

 

 

Quick Details

 

  • Fire Alarm Cable
  • FPL 18 AWG 2 Core
  • Solid Bare Copper Conductor 
  • Unshielded types: 2C / 4C / 6C / 8C
  • Shielded types: 2C / 4C / 6C / 8C
  • Non-Plenum PVC Jacket
  • 500FT, 1000FT, Wooden Reel, Carton
  • Power Limited Fire Alarm Systems
  • MOQ: 20 KM

 

Description

 

Zion communication ELECTRONICS is the leading manufacturer of fire alarm system cables for the fire protection industry. Our innovative product line includes all power-limited cables for use in the NEC Article 760. 
 
NATIONAL ELECTRIC CODE (NEC) ARTICLE 760: NEC Article 760 covers the installation of wiring and equipment of fire alarm systems,including all circutis controlled  and powered by the fire alarm system.
These systems are defined in the NEC as " The portion of wiring system between the load side of the overcurrent devices or the power-limited supply and the connected equipment of all circuits powered 
and controlled by the fire alarm system."
 
Type FPL- FPL power-limited fire alarm cable is listed by the NEC as being suitable for general purpose
fire alarm use.This listing excludes installation in riser, ducts, plenums and other spaceused for
environmental air unless the cable is installed in conduit.All FPL cables are listed as being resistant to
the spread of fire and must pass both UL test 1424 and the vertical flame testUL 1581.
 
 
 
 
KT1417 Fire Alarm Cable 18AWG 2 Core Solid Bare Copper Non-Plenum PVC
Application
Indoor for:
Audio Circuits
Control Circuits
Initiating Circuits
Notification Circuits
 
Properties
Temperature Rating:    '-20 to 75℃
Operating Voltage:       300 Volts max.
Flame Rating:              UL 1685 Vertical Tray
Insulation & Jacket:      PVC
Unshielded types
Conductors NOM.THICKNESS(MM) Nominal0.D.  Capacitance Impedance DC Resistance
Number Solid Insulation Jacket Inch pf/ft Ohms Ohms/M'
2 18 AWG 0.006" 0.015" 0.134" 20 81 6.5
4 18 AWG 0.006" 0.015" 0.170" 20 81 6.5
6 18 AWG 0.006" 0.015" 0.192" 20 81 6.5
8 18 AWG 0.006" 0.015" 0.208" 20 81 6.5
Shielded types
Conductors NOM.THICKNESS(MM) Nominal0.D.  Capacitance Impedance DC Resistance
Number Solid Insulation Jacket Inch pf/ft Ohms Ohms/M'
2 18 AWG 0.006" 0.015" 0.138" 42 36 6.5
4 18 AWG 0.006" 0.015" 0.160" 42 36 6.5
6 18 AWG 0.006" 0.015" 0.196" 42 36 6.5
8 18 AWG 0.006" 0.015" 0.212" 42 36 6.5
 
 Drain Wire     22 AWG Solid Tinned-Copper
 Shield     0.001" thick Aluminum/Mylar
 
Color
Number Description
2  Blk,Red
4 Blk,Red,Ylw,Grn
6 Blk,Red,Ylw,Grn,Brn,Blu
8 Blk,Red,Ylw,Grn,Brn,Blu,Ppl,Pnk
 
Order Informations:
Print

Zion communication KT1417 ×C20 E×××××××(UL) FPL OR 

CL2 SUN RES(ROHS) ××××FT                    
DEVICE/ZONE A B C D E F 1 2 3 4 5 6 7 8 9

Packing 500FT, 1000FT, Wooden Reel, Carton, Pallet
 

 

Competitive Advantage:

 

1,  From raw materials to final products, we perform intense quality checks to maintain our product quality:

     A, Incoming material inspected by QC.

     B, Manufacturing Process Control

     C: Workers trained daily/weekly/monthly

     D: Work instructions manual at each work station

     E: 5S system implemented

     F: Machine maintenance procedure

     G: Quality Control and Final Inspection 

         The QC staff will check the material, process product

         and final product according to the specification or test procedure.

 

2, Our R&D efforts center on reinforcing and developing element technologies

    needed to support the future growth and success for customers and Zion communication.

3, We know customers have urgent needs.

    We are skilled at effective communication to interact with customers.

    In order to provide prompt service, we can answer for you 7*24 hours.

4, We can Quickly and professionally answer for the inquire

5, More than 1000 kinds of cable, connectors and assembles can be produce and organized from us

6, Intime delivery

 

FPL Shielded Fire Alarm Cable 18 AWG 2 Core Non-Plenum PVC for Smoke Detectors 0

Contact Details
isaac lee

Phone Number : +8613285710822

WhatsApp : +8615088607575