KINGTONE ELECTRONICS CO.,LTD

      Best Supplier of CCTV & CATV Coaxial Cable,Lan Cable,

      Fire Alarm Cable and Cable Accessories!

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsFire Alarm Cable

16AWG 4 Core Fire Alarm Cable Solid Bare Copper Conductor with Non-Penum PVC

Certification
Good quality CATV Coaxial Cable for sales
Good quality CATV Coaxial Cable for sales
8 years' cooperation with KINGTONE Electronics, very good partner!

—— Alexander Valencia

Impressed by quick and professional answer each time, very satisfied with good and stable quality.

—— John Scott

We have received the Network Cable goods. They are of stable quality and we'll do more business in the future.

—— David Wilson

Competive price with outstanding quality of Fire Alarm Cable alll the time. We'll continue the long-term business for the mutual benefits!

—— Peter Barber

Quality Cables and Quality Serveice from Kingtone Electronics. Hope more business on RF Coaxial Cable business in 2017!

—— Nguyen Van Khien

I'm Online Chat Now

16AWG 4 Core Fire Alarm Cable Solid Bare Copper Conductor with Non-Penum PVC

China 16AWG 4 Core Fire Alarm Cable Solid Bare Copper Conductor with Non-Penum PVC supplier

Large Image :  16AWG 4 Core Fire Alarm Cable Solid Bare Copper Conductor with Non-Penum PVC

Product Details:

Place of Origin: China
Brand Name: KINGTONE OR OEM
Certification: ISO, CE, RoHS, UL
Model Number: Fire Alarm Cable 16AWG FPL

Payment & Shipping Terms:

Minimum Order Quantity: 20 KM
Packaging Details: 500FT, 1000FT, Wooden Reel, Carton
Delivery Time: 25 working days
Payment Terms: T/T, L/C
Supply Ability: 1000KM / Month
Detailed Product Description
Conductor: Solid Bare Copper Insulation: PVC Non-Plenum
Shield: Aluminum / Mylar Jacket: PVC Non-Plenum
Color: Red Package: 500FT, 1000FT, Wooden Reel, Carton

 

 

16AWG 4 Core Fire Alarm Cable Solid Bare Copper Conductor with Non-Penum PVC

 

 

 

Quick Details

 

  • Fire Alarm Cable
  • FPL 16 AWG 4 Core
  • Solid Bare Copper Conductor 
  • Unshielded Types: 2C / 4C
  • Shielded Types: 2C / 4C
  • Non-Plenum PVC Jacket
  • 500FT, 1000FT, Wooden Reel, Carton
  • Power Limited Fire Alarm System
  • MOQ: 20 KM

 

 

Description

 

KINGTONE ELECTRONICS is the leading manufacturer of fire alarm system cables for the fire protection industry. Our innovative product line includes all power-limited cables for use in the NEC Article 760. 
 
NATIONAL ELECTRIC CODE (NEC) ARTICLE 760: NEC Article 760 covers the installation of wiring and equipment of fire alarm systems,including all circutis controlled  and powered by the fire alarm system.
These systems are defined in the NEC as " The portion of wiring system between the load side of the overcurrent devices or the power-limited supply and the connected equipment of all circuits powered 
and controlled by the fire alarm system."
 
Type FPL- FPL power-limited fire alarm cable is listed by the NEC as being suitable for general purpose
fire alarm use.This listing excludes installation in riser, ducts, plenums and other spaceused for
environmental air unless the cable is installed in conduit.All FPL cables are listed as being resistant to
the spread of fire and must pass both UL test 1424 and the vertical flame testUL 1581.
 
 
 
KT1418 Fire Alarm Cables 16 AWG FPL-CL2 PVC Insulation Non-Plenum
Application
Indoor for:
Audio Circuits
Control Circuits
Initiating Circuits
Notification Circuits
 
Properties
Temperature Rating:    '-20 to 75℃
Operating Voltage:       300 Volts max.
Flame Rating:              UL 1685 Vertical Tray
Insulation & Jacket:      PVC
 
Unshielded types
Conductors NOM.THICKNESS(MM) Nominal0.D.  Capacitance Impedance DC Resistance
Number Solid Insulation Jacket Inch pf/ft Ohms Ohms/M'
2 16 AWG 0.006" 0.015" 0.158" 20 81 4.15
4 16 AWG 0.006" 0.015" 0.180" 20 81 4.15
Shielded types
Conductors NOM.THICKNESS(MM) Nominal0.D.  Capacitance Impedance DC Resistance
Number Solid Insulation Jacket Inch pf/ft Ohms Ohms/M'
2 16 AWG 0.006" 0.015" 0.160" 46 34 4.1
4 16 AWG 0.006" 0.015" 0.186" 46 34 4.1
 
  Drain Wire     20 AWG Solid Tinned-Copper
  Shield     0.001" thick Aluminum/Mylar
 
Color
Number Description
2 Blk,Red
4 Blk,Red,Ylw,Grn
 
Order Informations:
Print

KINGTONE KT1418 ×C16 E×××××××(UL) FPL 

OR CL2 SUN RES(ROHS) ××××FT                    
DEVICE/ZONE A B C D E F 1 2 3 4 5 6 7 8 9

Packing 1000FT/Pull Box, 1000FT/Spool, Pallet
 

 

Competitive Advantage:

 

1,  From raw materials to final products, we perform intense quality checks to maintain our product quality:

     A, Incoming material inspected by QC.

     B, Manufacturing Process Control

     C: Workers trained daily/weekly/monthly

     D: Work instructions manual at each work station

     E: 5S system implemented

     F: Machine maintenance procedure

     G: Quality Control and Final Inspection 

         The QC staff will check the material, process product

         and final product according to the specification or test procedure.

2, Our R&D efforts center on reinforcing and developing element technologies

    needed to support the future growth and success for customers and KINGTONE.

3, We know customers have urgent needs.

    We are skilled at effective communication to interact with customers.

    In order to provide prompt service, we can answer for you 7*24 hours.

4, We can Quickly and professionally answer for the inquire

5, More than 1000 kinds of cable, connectors and assembles can be produce and organized from us

6, Intime delivery

 

16AWG 4 Core Fire Alarm Cable Solid Bare Copper Conductor with Non-Penum PVC

Contact Details
KINGTONE ELECTRONICS CO.,LTD (1)

Contact Person: Luke

Send your inquiry directly to us (0 / 3000)